Click for more products.
No produts were found.
Customer ratings and reviews
TV400YK-EBSYS
New product
The TV400YK-EBSYS is a smart combination in large gel vertical electrophoresis and western blotting equipment. The system is applicable for miniGel PAGE (Native, SDS-PAGE, vertical IEF, 2DE) and protein transfers by electo-blotting using 20 x 20.5cm gels. The modular system and cooled tank provides for: higher voltages, shorter run times, greater resolution, and economy. The tank is leak free and constructed from 12mm acrylic, the cooling coil is electrically inert and thermally conductive located at the bottom of the gel tank. It is connected using snap-lock connectors to your choice of chiller or recirculating refrigerated water bath. The gel running module (GRM) holds the gels during electrophoresis and works with the gel casting base for a leak proof seal. The gel base unit includes Soft silicone gaskets in a robust precision engineered casting base.
Features include:
Complete system include:
Twin-plate maxi-gel unit with GRM and cooled gel tank, with built-in cooling coil and quick-fit tubing, lid, 2 x (20.5 x 20cm; W x H) plain glass plates, 2 x (20.5 x 20cm) notched glass plates, 1 x dummy plate, 4 x 1mm thick spacers, 2 x spacer aligners and 2 x 1mm thick 24-sample combs, casting baseand 2 x silicone seals; plus EBGRM, 2 x electroblotting cassettes and 4 x fibre pads.
Technical Specifications: |
||
|
TV100YK-SYS |
TV400YK |
Unit Dimensions (W x D x H) |
28.5 x 15 x 18cm |
38 x 15 x 27.5cm |
Inner Tank Dimensions (W x D x H) |
16.5 x 11 x 15cm |
27 x 12.5 x 25cm |
Plate Dimensions (W x H x T) |
10 x 10 x 0.2cm |
20.5 x 20 x 0.4cm |
Standard Spacer Dimensions (W x H x T) |
1 x 10 x 0.1cm |
2 x 20 x 0.1cm |
Active Gel Dimensions (W x H) |
8 x 8.5cm |
16.5 x 17.5cm |
Maximum Gel Capacity |
2 x 12 |
2 x 24 |
Recommended Buffer Volume |
Inner Buffer Chamber 90ml |
Inner Buffer Chamber 700ml |
Gel Tank 1600ml |
Gel Tank 4200ml |
|
Recommended Running Conditions for (Denaturing/Native PAGE Gel) |
Voltage 100 - 150V (10 - 15V/cm) |
Voltage 200 – 300 V (10-15V/cm) |
Current 10 - 15mA |
Current 30 - 40mA |
|
Time 1 - 1.75h |
Time 2 - 2.5h |
|
Distance Between Blotting Plate |
6cm |
6cm |
Electroblotting Cassette Dim. (W x L) |
11.5 x 10.5cm |
20.5 x 20cm |
Active Transfer Area |
71cm2 |
289cm2 |
Recommended Running Conditions for Electroblotting |
Voltage 100V |
Voltage 200V |
75mA (0.6-0.8mA/cm2) |
150mA (0.8-1.0mA/cm2) |
|
Time 4 – 6hrs |
6h to overnight |
|
Snap-lock Connectors for Cooling Coil |
Inner Diameter = 10mm
|
|
Outer Diameter = 12mm |
|
|
Quick-fit Tubing |
Inner Diameter = 10mm |
Inner Diameter 10mm |
Outer Diameter = 12mm |
Outer Diameter 12mm |
|
Casting Base Silicone Seal Dimensions |
1.5 x 11 x 0.8cm |
1.7 x 22.5 x 0.8cm |
Power Output Connectors (diameter) |
Shrouded, 4mm |
Shrouded, 4mm |
Recommended Power Supply |
Consort EV215 or EV261 |
Consort EV215 or EV261 |