TV100YK - 2DSYS, mini Gel 2D Electrophoresis System, Scie-plas

price $1,121.76

TV100YK - 2DSYS

Less more

Comodo SSL

Customer ratings and reviews

Nobody has posted a review yet
in this language

Rate / write a comment

TV100YK - 2DSYS, mini Gel 2D Electrophoresis System, (10 x 10cm), Scie-plas

 

The TV100YK-2DSYS complete modular system providing a fully integrated solution with one gel tank for 2-D electrophoresis, using 10 x 10cm gels, and capillary isoelectric focusing (IEF). The system combines a gel running module, capillary IEF module with a cooled electrophoresis chamber. Perform 2DE, IEF, and Native and SDSPAGE when needed. A smart combination in vertical mini gel electrophoresis and IEF for 2DE applications. The cooled tank provides for: higher voltages, shorter run times, greater resolution and economy.  The tank is leak free and constructed from 12mm acrylic, the cooling coil is electrically inert and  located at the bottom of the gel tank. It is connected using snap-lock connectors to your choice of chiller or recirculating refrigerated water bath. The gel running module (GRM) holds the gels during electrophoresis and works with the gel casting base for a leak proof seal. The gel base unit includes Soft silicone gaskets in a robust precision engineered casting base. The capillary gel running module can be used for analytical (as supplied) or protein isolation (option) applications.

 

Features include:

 

  • Cooled Tank
  • Modular Cassettes
    • miniGel Electrophoresis
    • Capillary Running Module
    • Gel Casting
    • Capacity:
      • 2 mini Gels (10 x 10cm)
      • 10 IEF gels (1mm x 5mm x 80mm)
      • Electrodes: 99.99% with Gold plated connectors
      • 3 year manfucturer’s warranty

 

 Complete system includes:

  • Twin-plate mini-gel unit with GRM and cooled gel tank, with built-in cooling coil and quick-fit tubing, lid, 2 x (10 x 10cm; W x H) plain glass plates, 2 x (10 x 10cm) notched glass plates, 1 x dummy plate, 4 x 1mm thick spacers, 2 x spacer aligners and 2 x 1mm thick 12-sample combs, casting base and 2 x silicone seals; CAPGRM, 10 x 1mm glass capillaries, 4 x 1.5mm thick spacers, 2 x 1.5mm thick, 1-D preparatory combs, 10 x blanking ports and 1 x gel extraction platform

 

Technical Specifications:

 

TV100YK-2DSYS

TV400YK-2DSYS

Unit Dimensions (W x D x H)

28.5 x 15 x 18cm

38 x 15 x 27.5cm

Inner Tank Dimensions (W x D x H)

16.5 x 11 x 15cm

27 x 12.5 x 25cm

Plate Dimensions (W x H x T)

10 x 10 x 0.2cm

20.5 x 20 x 0.4cm

Standard Spacer Dimensions (W x H x T)

1 x 10 x 0.1cm

2 x 20 x 0.1cm

Active Gel Dimensions (W x H)

8 x 8.5cm

16.5 x 17.5cm

Maximum Gel Capacity

2 x ½ x 12

2 x 24

Recommended Buffer Volume

Inner Buffer Chamber: 90ml

Inner Buffer Chamber: 700ml

Gel Tank: 1600ml

Gel Tank: 4200ml

Recommended Running Conditions for

(Denaturing/Native PAGE Gel)

Voltage 100 - 150V

(10 - 15V/cm)

Voltage 200 – 300 V

(10-15V/cm)

Current 10 - 15mA

Current 30 - 40mA

Time 1 - 1.75h

Time 2 - 2.5h

Capillary Dimensions (ID x OD x L)

1mm x 5mm x 80mm

1mm x 5mm x 170mm

Recommended Buffer Volume

200ml

200ml

1600ml

1600ml

Recommended Running Conditions for

Capillary IEF

Voltages: 200v,  400v, 500v

Voltages: 200v, 400v,    500v

Times:     0.5hr,   3hr,  0.5hr

Times:     0.5hr, 6-18hr,  0.5hr

Volt-hr:    100/Vh, 1200Vh, 250Vh

Volt-hr:  100Ch, 2400Vh, 250 –

                                     7200Vh                 

Snap-lock Connectors for Cooling Coil

Inner Diameter = 10mm

Inner Diameter = 10mm

Outer Diameter = 12mm

Outer Diameter = 12mm

Quick-fit Tubing

Inner Diameter = 10mm

Inner Diameter 10mm

Outer Diameter = 12mm

Outer Diameter 12mm

Casting Base Silicone Seal Dimensions

1.5 x 11 x 0.8cm

1.7 x 22.5 x 0.8cm

Power Output Connectors (diameter)

Shrouded, 4mm

Shrouded, 4mm

Recommended Power Supply

Consort EV215 or EV261

Consort EV215 or EV261

 

 

 